Identification methods for radiation cross-linked low smoke zero halogen flame retardant wires and cables

2025-05-14 09:19:33
times

Irradiated cross-linked low smoke zero halogen flame retardant wires and cables have been widely recognized by electricians and electrical practitioners for their excellent comprehensive electrical and physical properties, and have been applied in many key projects, demonstrating a promising market prospect. However, it is worrying that in recent years, some phenomena of imitation and even counterfeiting of this product have been discovered, seriously threatening the engineering quality and image of key construction projects.


Here, the editor has summarized some methods for identifying irradiated cross-linked low smoke zero halogen flame retardant wires and cables, hoping they will be helpful to you


1. Heat with an electric soldering iron


If you heat the insulation layer with an electric soldering iron, there should be no obvious dent. If there is a large dent, it indicates that there is a defect in the material or process used for the insulation layer.


2. Lighter burning


When using a lighter to grill, under normal circumstances, it should be difficult to catch fire. After a long period of burning, the insulation layer of the cable remains relatively intact, without thick smoke or pungent smell, and at the same time, the diameter has increased. If it is very easy to ignite, it can be determined that the insulation layer of the cable does not use low smoke zero halogen materials. If there is a large amount of smoke, it indicates that the insulating layer is made of halogen-containing materials. If the insulation surface peaking is severe after long-term burning and the diameter does not increase significantly, it indicates that the appropriate irradiation crosslinking process treatment has not been carried out.


3. Density comparison


The density of low smoke zero halogen materials is greater than that of water. A small amount of the insulating layer can be peeled off and put into water. If it floats above the water surface, it is definitely not a low smoke zero halogen material.


Tags

  • menu

Telephone: 0755-84890888, 0755-89996999

Suggestion, communication, coordination and complaint channels: 13802568348 (same number for wechat)

Company email: bdk01@163.com

Address: No. 58, Cuijing Road, Pingshan District, Shenzhen City


微信图片_20250807093820

Video Account QR code

奔达康公众号

Qr code of the official account

抖音

Tik Tok QR code

微视

Qr code of Weishi Account

Copyright © Shenzhen Bendakang Cable Co., Ltd All rights reserved record number:粤ICP备18103626号 Mainly engaged inHome decoration wires, fire-resistant cables, and power cable manufacturers, Welcome to inquire! Technical Support: 华企立方 disclaimer
#
在线客服

x