产品展示

产品展示

Indoor telephone communication cable

Indoor telephone communication cable

  • Category:Signal transmission cable
  • Browse number:
  • QR code:
  • Release time:2023-08-01 09:58:41
  • Product description

Indoor (outdoor) telephone communication cables are suitable for wiring in telecommunication engineering, serving as links between floor wiring systems in communication systems. They can also be used for connections between communication outlets (information sockets) and telecommunication equipment (such as telephones, faxes, etc.). In areas with severe interference, shielded cables should be used.

Multi-pair local communication cables are produced in accordance with the standard twisted pitch of digital cables, which reduces the mutual crosstalk interference between pairs, thereby reducing the crosstalk attenuation of the cables and minimizing power loss. It is used for audio connection between the main distribution frame within the program-controlled switching office and the users of the switching office, and can support low-rate data transmission. Connections include digital telephones, faxes, program-controlled switches and other digital communication devices. 4 pairs are used for the connection of branch lines in telecommunication engineering cabling, and 10 pairs, 20 pairs, 30 pairs, 50 pairs, 100 pairs, etc. are used for the connection of main lines.


Indoor telephone communication cable


HYV - Polyolefin insulated polyvinyl chloride sheathed indoor telephone communication cable


Recommended specifications


Conductor diameter: 0.4mm, 0.5mm


Recommended logarithms: 1 pair, 2 pairs, 3 pairs, 4 pairs, 5 pairs, 10 pairs, 20 pairs, 30 pairs, 50 pairs, 100 pairs


Product color: White (for indoor use), black (for outdoor use


Cables should be protected from mechanical external forces, overheating, corrosion, radiation, wear and other hazards. The laying of cables requires a favorable external environment. If they are easily disturbed by adverse factors, it will increase the damage and destruction to them, and easily lead to line faults and accidents.


2. In the same project or cable channel, the principle of arranging from strong current to weak current in an up-down sequence should be followed, with communication cables placed at the bottom.


The long-term allowable operating temperature of the conductor is -40℃ to +50℃, and the monthly average maximum relative humidity is 95% (+25℃).


4. The allowable temperature for cable laying and installation shall not be lower than -10℃.


The minimum bending radius of the cable is 15 times the outer diameter of the cable.



Previous:Outdoor communication cable2023-08-01
Next:Computer cable2023-08-01
  • menu

Telephone: 0755-84890888, 0755-89996999

Suggestion, communication, coordination and complaint channels: 13802568348 (same number for wechat)

Company email: bdk01@163.com

Address: No. 58, Cuijing Road, Pingshan District, Shenzhen City


微信图片_20250807093820

Video Account QR code

奔达康公众号

Qr code of the official account

抖音

Tik Tok QR code

微视

Qr code of Weishi Account

Copyright © Shenzhen Bendakang Cable Co., Ltd All rights reserved record number:粤ICP备18103626号 Mainly engaged inHome decoration wires, fire-resistant cables, and power cable manufacturers, Welcome to inquire! Technical Support: 华企立方 disclaimer
#
在线客服

x